BLDCD - INDUSTRIAL EMAMELS, 977

  • MSDS: BLDCD
  • Manufacturer: RUST OLEUM CORP
  • Product Name: INDUSTRIAL EMAMELS, 977
  • National Stock Number: 8010-01-087-9102
Product Identification

Product ID:INDUSTRIAL EMAMELS, 977
MSDS Date:01/03/1990
FSC:8010
NIIN:01-087-9102
MSDS Number: BLDCD

Responsible Party
RUST-OLEUM CORP
11 HAWTHORN PKWY
VERNON HILLS, IL 60061
US

Emergency Phone: 708-367-7700

Info Phone: 708-367-7700

Cage: 08882

Contractor
RUST-OLEUM CORP
VERNON HILLS, IL 60061-1583 US

Telephone: 847-367-7700

Cage: 08882

Ingredients

STODDARD SOLVENT

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 30-55%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9293

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NACUTE: INHAL:HARMFUL IF INHALED. MAY
EFFECT BRAIN AND NERVOUS SYSTEM CAUSING DIZZ, HEADACHE AND NAUSEA.
REPEATED OVEREXPOSURE MAY LEAD PROGRESSIVELY TO STAGGERING GAIT,
CONFUSION, UNCONSCIOUSNESS OR COMA. CAUSES NOSE AND THROAT
IRRITATION. ACUTE:SKIN OR EYE CONTACT:CAUSES EYE AND SKIN IRRIT
WHICH (FPTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CAN LEAD TO DERMATITIS WITH REPEATED
OVEREXPOSURE. INGEST:GASTROINTESTINAL IRRITATION, NAUSEA, VOMITING
AND DIARRHEA. CHRONIC: REPORTS HAVE SHOWN REPEATED AND PROLONGED
OCCUPATIONAL OVEREXPOS URE TO SOLVENTS WITH PERMANENT BRAIN AND
NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE FROM EXPOS, RESTORE BRTHG, AND NOTIFY PHYSICIAN.
EYE:FLUSH IMMED W/LARGE AMTS OF WATER FOR AT LEAST 15 MIN. NOTIFY
PHYSICIAN. SKIN:WASH AFFECTED AREA WITH SOAP AND WATER, REMOVE
CONTAM CL OTHING, & WASH BEFORE REUSE. INGEST:DO NOT INDUCE
VOMITING. KEEP PERSON WARM, QUIET, AND GET MEDICAL ATTENTION.
ASPIRATION OF THIS MATL INTO LUNGS CAN CAUSE CHEMICAL PNEUMONITIS
WHICH CAN BE FATAL.

Fire Fighting

Flash Point Method:TCC
Flash Point:104F, 40C
Extinguishing Media:NFPA CLASS B EXTINGUISHERS (CARBON DIOXIDE, DRY
CHEMICAL, OR FOAM).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROT
EQUIP SHOULD BE USED. WATER SPRAY MAY BE INEFFECTIVE. WATER MAY BE
USED (SUP DAT).
Unusual Fire/Explosion Hazard:KEEP CNTNR TIGHTLY CLSD. ISOLATE FROM
HEAT, ELECTRICAL EQUIP, SPARKS, & OPEN FLAME. CLSD CNTNR MAY
EXPLODE WHEN EXPOS TO EXTREME HEAT. DO NOT APPLY TO HOT SURF.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE AREA
AND REMOVE WITH INERT ABSORBENT AND NON-SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
QUANTITIES IN BUILDING DESIGNED AND PROTECTED FOR STORAGE OF NFPA
CLASS II COMBUSTIBLE LIQUIDS.
Other Precautions:CONTAINERS SHOULD BE GROUNDED WHEN POURING. EMPTY
CONTAINERS MAY BE HAZARDOUS.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED CHEMICAL CARTRIDGE
RESPIRATOR (TC23C).
Ventilation:PROVIDE GEN DILUTION OR LOCAL EXHAUST VENT IN VOLUME, &
PATTERN TO KEEP TLV OF HAZARDOUS INGRED BELOW ACCEPTABLE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:USE IMPERVIOUS GLOVES &/OR CLTHG TO PVNT
PRLNG SKIN CONTACT. IN CONFINED AREAS USE NIOSH/MSHA APPRVD
SUPPLIED (SUP DAT)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
UNSUAL FIRE HAZ:TO COOL CLOSED CONTAINERS TO PREVENT PRESSURE BUILD-UP
AND POSSIBLE AUTOIGNITION OR EXPLOSION. IF WATER IS USED, FOG
RESPIRATOR OR HOODS (TC19C).

Chemical Properties

Boiling Pt:B.P. Text:307F, 153C
Vapor Density:>THAN AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:51-66%

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS. BY OPEN FLAME-CARBON MONOXIDE AND CARBON
DIOXIDE.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:BY OPEN-FLAME-CARBON MONOXIDE AND
CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.